A boiler is a closed vessel in which water or other fluid is heated. Most boilers produce steam to be used at saturation temperature; that is, saturated steam.

Superheated steam boilers vaporize the water and then further heat the steam in a superheater. This provides steam at much higher temperature, but can decrease the overall thermal efficiency of the steam generating plant because the higher steam temperature requires a higher flue gas exhaust temperature.

We are an experienced steam boiler contractor that brings unparalleled knowledge, skill, and resources to your project.


蒸汽燃源整合服務

 

Project Evaluation

The main item of project evaluation

  1. The existing of steam boilers capacity
  2. The existing of steam boilers quantity
  3. The existing of steam boilers pressure
  4. The existing of steam boilers temperature
  5. Boiler feed water temperature
  6. Types of fuel
  7. Steam boilers at maximum load condition
  8. An average steam per month


The benefits of project evaluation

蒸汽燃源專案評估

 

Operation Management

Project Management Team

Personal Management(PM) : Group of Senior Management

Boiler Operator, technician:
Class A technician for boiler operator 15 employees、 Class B technician for boiler operator 3 employees、 Class B technician for boiler operator 3 employees、 Water pollution control specialist 1 employee、 Occupational Safety and Health Manager 2 employees

Business Plan
營運計畫蒸汽燃源

Operation Management Programs
Boiler run during 2hours, operator will check this procedure
鍋爐運行管理

 

Layout of equipment

棕櫚殼炭化爐


Main technical data :
Item Model Production Boiler Efficiency Weight Floor Space
YHTJ450-I 350kg/h 19.5kw 11T 10*6m
YHTJ450-II 700kg/h 27kw 14T 10*6m

Flow Chart References
鍋爐參考流程圖

鍋爐參考流程圖

Configurations

鍋爐參考配置圖

Diagram of a boiler
鍋爐參考側視圖

Prevention stationary source configuration

Technology can prevent or limit the pollution from industrial and commercial facilities. The air facility permit is the principal vehicle for requiring these measures. Operating permits are legally enforceable documents issued to air pollution sources, specifying the air pollution control requirements for the facility. Operating sources must comply with the terms of this permit.

固定汙染源防制配置

In the past, the primary origin of local air pollution has been emissions from stationary sources. These sites include power generating plants, oil refineries, chemical plants, steel factories, cement, and many other industries. Pollutants are emitted into the air from these plants through fossil fuel combustion, chemical processes, and the grinding or pulverizing of metals for cement, fertilizers, etc. These processes emit a number of harmful contaminants into the air. The most damaging being sulfur dioxide, nitrogen oxides, carbon dioxide, synthetic compounds, and particulate matter.

塵集塵器、斗昇機、儲料倉、分配器

Discharge standard of water pollutants
  Discharge Standard Remark : Solid Fuel
Particulate pollutant New:50 mg/Nm3
Old:100 mg/Nm3
combustion process
Nitrogen Oxides (NOX) New:350 mg/Nm3
Old:500 mg/Nm3
 
Sulfur Oxides (SOX) New:300 mg/Nm3
Old:300 mg/Nm3
 
Opacity It does not exceed 20%
Stop-start can reach 40%
accumulated time does not exceed 3 minutes in an hour
 